Solar Pump Inverter Brushless Controller Wind Generators Single Phase AC Motor

two.1 Naming and nameplate identification
two.1.one Naming rule
SI300-0R7G-4

 

Identification Voltage amount
4 a few-period 380V
S2 One-phase 220V

 

Identification Adaptive motor type
G CZPT kind

 

Identification .4 .75 four hundred
Adaptive motor(KW) .4 .75 400

two.2 Introduction of numerous components of the converter
The framework types of JAC580N collection converter are the plastic and steel. The external diagram is proven beneath.

2.3 Standard complex specification 
Desk 2-1 CZPT specification of 580N sequence frequency converter

Item Specification
CZPT capabilities Highest frequency Vector handle: ~500Hz V/F manage: ~500Hz
Provider frequency .8kHz~12kHz
The provider frequency is automatically modified dependent on the load characteristics.
Enter frequency
resolution
Digital environment: .01Hz
Analog environment: highest frequency x .571%
Management mode • Open-loop vector control (SVC)
• Closed-loop vector handle (FVC)
• Voltage/Frequency (V/F) management
CZPTting torque • G type: .five Hz/a hundred and fifty% (SVC) Hz/a hundred and eighty% (FVC)
• P type: .five Hz/a hundred%

Standard functions

Velocity range 1:one hundred  (SVC) 1:one thousand  (FVC)
Consistent-velocity accuracy ± .5%  (SVC) ± .02%  (FVC)
Overload potential • G kind:60s for a hundred and fifty% of the rated existing
• P variety: 60s for a hundred and twenty% of the rated present.
Torque enhance • Set enhance
• CZPTized increase .1%-30.%
V/F curve • Straight-line V/F curve
• Multi-stage V/F curve
•N-energy V/F curve (one.two-electrical power, one.four-energy, 1.six-electrical power, ,one.8-power, square)
V/F separation Two kinds: comprehensive separation 50 percent separation
Acceleration /deceleration curve • Straight-line ramp
• S-curve ramp
Four teams of acceleration/deceleration time with the
range of .-6500.0s
DC braking DC braking frequency: .00Hz~greatest frequency
Braking time: .0s~36.0s
Braking motion present price: .%-a hundred.%
JOG management JOG frequency range: .00-50.00 Hz
JOG acceleration/deceleration time: .-6500.0s
Operation Command supply Procedure panel, manage terminal and serial interaction port are offered
Switch in different strategies
Frequency resource Numerous frequency resources: digital reference, analog voltage reference, analog existing reference, pulse reference and serial port reference. The switching can be carried out in numerous approaches
Auxiliary frequency supply ten sorts of auxiliary frequency resource. The auxiliary frequency jog and frequency synthesis can be attained flexibly
Enter terminal CZPTs:
seven digital input terminals, among which a single assistance maximum large-pace pulse enter of 100kHz
2 analog input terminals, amongst which one only supports voltage input of ~10V and the other supports voltage input of ~10V or recent input of four ~20mA
Enlargement ability:
3 digital enter terminals
1 analog input terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000
Output terminal CZPTs:
one higher-velocity pulse output terminal (The open collector kind is optional), supporting ~100kHz sq. signal output
one digital output terminal
1 relay output terminal
one analog output terminal, supporting recent output of ~20mA or voltage output of ~10V
Enlargement ability:
one digital output terminal
one relay output terminal
1 analog output terminal, supporting current output of ~20mA or voltage output of ~10V
Show and keyboard operation LED show Exhibit the parameter
Essential lock and operate choice Comprehend partial or all key lock and outline the motion assortment of some keys to avert misoperation
Security operate Brief circuit check of electrified motor, input/output default phase protection, overcurrent safety, overvoltage safety, undervoltage safety, overheat defense, overload safety, and so on.

 

Solar Pump Inverter Brushless Controller Wind Generators Single Phase AC Motor